BPDMQ - PDL 1003 A COMPONENT

Product Identification

Product ID:PDL 1003 A COMPONENT
MSDS Date:11/08/1990
FSC:8030
NIIN:00N030053
Kit Part:Y
MSDS Number: BPDMQ

Responsible Party
POLYMER DEVELOPMENT LABS INC
212 W TAFT AVE
ORANGE, CA 92665
US

Emergency Phone: 714-921-2300;800-424-9300(CHEMTREC)

Info Phone: 714-921-2300

Preparer: EZZAT SEIF

Cage: 1N060

Contractor
POLYMER DEVELOPMENT LABORATORIES INC
ORANGE, CA 92665-4220 US

Telephone: 714-921-2300

Cage: 1N060

Ingredients

TEMPORARY CNTRL OF ISOCYANATE VAP IS REQD, BLANKET

RTECS: 9999999ZZ


BE PUMPED INTO CLSD BUT NOT SEALED CNTNRS FOR DISP.

RTECS: 9999999ZZ


W/1-2% ADDED DETERGENT, LETTING IT STAND OVER

RTECS: 9999999ZZ


USED FOR THIS WITH PLASTIC AND DISPOSE OF PROPERLY

RTECS: 9999999ZZ


SHOWERS & EYE WASH STATIONS SHOULD BE

RTECS: 9999999ZZ


ISOCYANIC ACID, METHYLENEDI-P-PHENYLENE ESTER;

CAS: 101-68-8

RTECS: NQ9350000

Fraction By Weight: 35-45%

OSHA PEL 0.02 PPM, C

ACGIH TLV: 0.005 PPM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


BENZENE, ISOCYANATO-; (PHENYL ISOCYANATE)

CAS: 103-71-9

RTECS: DA3675000

Fraction By Weight: TRACE


POLYMETHYLENE POLYPHENYL ISOCYANATE; (HIGHER OLIGOMERS OF

CAS: 9016-87-9

RTECS: TR0350000

Fraction By Weight: 35-45%


OF MIX OF H*2O & 3-8% CONC AMMONIUM

RTECS: 9999999ZZ


PART OF ISOCYANATE W/MIX. ALL TO STAND 48 HOURS

RTECS: 9999999ZZ


(714) 921-2300. IF IS TRANSPORTATION SPILL NOTIFY

RTECS: 9999999ZZ


SPILL TO PVNT ENTRY INTO ENVIRON. WEAR FULL PROT

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) >20 G/KG.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:MAY CAUSE RESP SENSIT IN
SUSCEPTIBLE INDIV AT ROOM TEMP, VAPS ARE MINIMAL DUE TO LOW VAP
PRESS. IF HEATED/ SPRAYED AS AN AEROSOL, EXCESSIVE CONC ARE
ATTAINABLE THAT COULD BE HAZ ON SINGLE EXPOS. EXCESSIVE EXPOS MAY
CAUSE IRRIT TO EYES, UPPER RESP TRACT & LUNGS. EFTS MAY BE DELAYED.
DECREASED VENT (EFTS OF OVEREXP
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CAPACITY HAS BEEN ASSOC W/EXPOS TO
SIMILAR ISOCYANATES;IT IS POSS THAT EXPOS TO MDI MAY CAUSE
IMPAIRMENT OF LUNG FUNC. SKIN:MAY CAUSE ALLERGIC SKIN RXN IN
SUSCEPTIBLE INDIV. PRLNGD/ RPTD CONT MAY CAUSE SKIN IRRIT. MAY
STAIN SKIN. MDI HAS BEEN REPORTED BY NIOSH TO BE MUTAGENIC TO
SALMONELLA TYPHIMURIUM BACTERIA
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE: FLUSH W/CLEAN, LUKE-WARM H2O AT LOW PRESS FOR AT LEAST
15 MIN, OCCAS LIFTING EYELIDS. CONSULT PHYS IMMED. SKIN: REMOVE
CONTAM CLTHG. WASH EXPOS AREA W/WARM SOAPY H2O THORO. CONTAM CLTHG
SHD BE PR OPERLY LAUNDERED BEFORE REUSING. INHAL:REMOVE VICTIM FROM
AREA OF EXPOS TO SAFE AREA. IF NOT BRTHG, GIVE MOUTH TO MOUTH
RESUSCITATION. IF BRTHG IS DFCLT, GIVE O2. CONSULT PHYS IMMED.
(SUPP DATA)

Fire Fighting

Flash Point Method:COC
Flash Point:425F,218C
Extinguishing Media:DRY CHEM EXTING SUCH AS MONOAMMONIUM PHOSPHATE,
POTASSIUM SULFATE, POTASSIUM CHLORIDE. ADDNLY, CO2, HIGH (SUPP
DATA)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . IF H2O USED, USE LRG AMTS AS RXN BETWEEN HOT
ISOCYANATES & H2O CAN BE VIGOROUS.
Unusual Fire/Explosion Hazard:WATER CONTAMINATION WILL PRODUCE CARBON
DIOXIDE. DO NOT RE-SEAL CONTAMINATED CONTAINERS AS PRESSURE BUILDUP
MAY RUPTURE THEM.

Accidental Release

Spill Release Procedures:MINOR SPILLS: CONTAIN SPILLED MATL & COVER
W/LOOSE ABSORB MATL SUCH AS OILDRY, VERMICULITE, SAWDUST/FULLER'S
EARTH. SHOVEL WASTE MATL INTO PROPER WASTE CNTNRS.DO NOT MAKE PRESS
TIGHT. TRANSPORT TO WEL L-VENT AREA & TREAT W/NEUT SOLN CONSISTING
(ING 4)
Neutralizing Agent:MIXTURE OF H2O & 3-8% CONC AMMONIUM HYDROXIDE OR 5-
10% SODIUM CARBONATE.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:PROD HAS DEMONSTRATED NO OBSERVABLE EFTS AT ROOM
TEMP.HOWEVER, ATMOSPHERIC LEVS SHOULD BE MAINTAINED.IN ADDN,IN ANY
SPRAY APPLIC/SITUATION WHERE AIRBORNE PARTICULATES/AEROSOL ARE
GENERATED,NIOSH/ MSHA APPRVD SUPP AIR SOURCE MUST BE PROVIDED
Ventilation:NATURAL/MECH. LOC EXHST WILL KEEP TLV BELOW MINIMUM IN MOST
CASES.SPILLS OR OTHER EMER MAY REQ MORE FORCEFUL VENT MEANS.
Protective Gloves:NATURAL RUBBER/POLYVINYL ALCOHOL GLOVES.
Eye Protection:CHEM WORK GOG & FULL LGTH FACESHLD
Other Protective Equipment:COVER AS MUCH EXPOS SKIN AS POSS W/APPROP
CLTHG. IF SKIN CREAMS USED,KEEP AREA COVERED BY CREAM TO A
MIN.SAFETY (ING 12)
Work Hygienic Practices:NO CONTACT LENSES SHOULD BE WORN.
Supplemental Safety and Health
EXTING MEDIA: EXPANSION (PROTEINIC) CHEM FOAM, H2O SPRAY FOR LRG FIRES.
FIRST AID PROC: INGEST: CALL MD IMMED . NOTE TO PHYS: NO SPECIFIC
ANTIDOTE. SUPPORTIVE CARE. TREATMENT BASED ON JUDGEMENT/ PHYS IN
RESPONSE TO RXNS OF PATIENT. MANIFESTATIONS FROM ACUTE EXPOS MAY BE
DELAYED. MAY CAUSE RESP SENSIT.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:645F,341C
Melt/Freeze Pt:M.P/F.P Text:<60F,<16C
Decomp Temp:Decomp Text:645F,341C
Vapor Pres:<0.0001
Vapor Density:8.6
Spec Gravity:1.2
Solubility in Water:REACTS
Appearance and Odor:VISCOUS LIGHT TO DARK BROWN LIQUID, SLIGHTLY
AROMATIC OR MUSTY ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
H2O, ACID, BASES, METAL COMPOUNDS AND SURFACE ACTIVE MATERIALS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:ISOCYANATE VAPOR AND MIST. CO2, CO.
NITROGEN OXIDES AND TRACES OF HYDROGEN CYANIDE.
Conditions to Avoid Polymerization:INCOMPAT REACTANTS, STRONG BASES,
H2O/TEMP >347F (175C). TEMP > 120F (49C) ACCELERATE REACTION WITH
WATER.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE,
AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.